Case ID (from Final Report) |
Mixing Time (Hrs) |
Mixing Time (Okita Units) |
|
A.1 Sq-no pillars; simultaneous fill/draw; Inlet Off-Center on Sidewall |
5.0 |
2.0 |
|
A.2 Sq-3 pillars; simultaneous fill/draw; Inlet Off-Center on Sidewall |
5.5 |
2.8 |
|
A.3 Sq-100 pillars; simultaneous fill/draw; Inlet Off-Center on Sidewall |
9.2 |
4.6 |
|
B.1 Sq-100 pillars; fill; Inlet Off-Center on Sidewall |
9.2 |
4.6 |
|
B.1 Sq-no pillars; fill, Inlet at Center of Sidewall |
3.0 |
1.5 |
|
C.1 EBMUD, Cyl-Warm; Edge Inlet; fill |
6.3 |
1.5 |
|
C.2 EBMUD, Cyl-Cool; Edge Inlet; fill |
5.8 |
1.4 |
|
C.3 EBMUD, Cyl-Isothermal; Edge Inlet; fill |
6.3 |
1.5 |
|
D.1 Cyl-Warm; Off-Center Inlet; fill |
6.7 |
1.8 |
|
D.2 Cyl-Cool; Off-Center Inlet; fill |
8.6 |
2.3 |
|
D.3 Cyl-Isothermal; Off-Center Inlet; fill |
8.6 |
2.3 |
|
E.1 Cyl-Warm; Center Inlet; fill |
4.8 |
1.3 |
|
E.2 Cyl-Warmer; Center Inlet; fill |
4.8 |
1.3 |
|
E.3 Cyl-Isothermal; Center Inlet; fill |
3.6 |
1.0 |
|
F.1 Ed Heck, Azusa, Cyl-Isothermal: Tangential Inlet; simultaneous fill/draw |
10.3 |
4.7 |
|
G.1 Brentwood, Baseline Baffle Wall; fill, draw, fill, draw |
23.1 |
6.2 |
|
G.2 Brentwood, Baffle Wall with 3 Gaps Wall; fill, draw, fill, draw |
12.8 |
3.5 |